Description
TAL30 - 3-pole Contactors - DC Operated
Bill of material
ABB - 1SBL283060R5110 + TAL30-30-10RT 17-32V DC Contactor
Product ID
1SBL283060R5110
Extended Product Type
TAL30-30-10RT 17-32V DC
Invoice Description
TAL30-30-10RT 17-32V DC Contactor
Description
Screw Terminals
Long Description
TAL30 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The TAL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. TAL... contactors are fitted with low consumption DC coils and offer a large coil voltage range.
International product number
3471522363510
Product number of the Manufacturer
1SBL283060R5110
Rated control supply voltage Us at AC 50HZ
- - - V
Rated control supply voltage Us at AC 60HZ
- - - V
Rated control supply voltage Us at DC
17 - 32 V
Voltage type for actuating
DC
Rated operation current Ie at AC-1, 400 V
50
A
Rated operation current Ie at AC-3, 400 V
32 A
Rated operation power at AC-3, 400 V
15 kW
Modular version
false
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Other
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
3
Customs tariff number
85364900
Deeplink product page
Link to product detail page
Type
TAL 30-30-10
Preview - Generation
Preview
3D
Dimension
2D

Classifications
ETIM 10.0
Power contactor, AC switching:
Suitable for distribution board: false
Rated operation power at AC-3, 400 V: 15 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 1
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie at AC-3, 400 V: 32 A
Rated operation current Ie at AC-1, 400 V: 50 A
Rated control supply voltage AC 50 Hz: - - - V
Rated control supply voltage AC 60 Hz: - - - V
Rated control supply voltage DC: 17 - 32 V
Type of electrical connection of main circuit: Other
Voltage type for actuating: DC
CNS
Object Properties:
Order Number: 1SBL283060R5110
Description long: TAL30 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The TAL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. TAL... contactors are fitted with low consumption DC coils and offer a large coil voltage range.
Description short: TAL30-30-10RT 17-32V DC Contactor
Manufacturer / brand name: ABB
Product website: https://new.abb.com/products/ABB1SBL283060R5110
Customs Tariff Number: 85364900
GTIN-Code: 3471522363510
ETIM 8.0
Power contactor, AC switching:
Modular version: false
Rated operation power at AC-3, 400 V: 15 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 1
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie at AC-3, 400 V: 32 A
Rated operation current Ie at AC-1, 400 V: 50 A
Rated control supply voltage Us at AC 50HZ: - - - V
Rated control supply voltage Us at AC 60HZ: - - - V
Rated control supply voltage Us at DC: 17 - 32 V
Type of electrical connection of main circuit: Other
Voltage type for actuating: DC
ETIM 9.0
Power contactor, AC switching:
Modular version: false
Rated operation power at AC-3, 400 V: 15 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 1
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie at AC-3, 400 V: 32 A
Rated operation current Ie at AC-1, 400 V: 50 A
Rated control supply voltage AC 50 Hz: - - - V
Rated control supply voltage AC 60 Hz: - - - V
Rated control supply voltage DC: 17 - 32 V
Type of electrical connection of main circuit: Other
Voltage type for actuating: DC
cadenas_class
:
eclass
27-37-10-03 - Power contactor, AC switching:
Rated operating power with AC-3, 400 V: 15 kW
Rated operating current Ie with AC-1, 400 V: 50 A
Rated operating current Ie with AC-3, 400 V: 32 A
max. rated control supply voltage Us: - - - V
min. rated control voltage Us with AC 50 Hz: - - - V
min. rated control voltage Us with AC 60 Hz: - - - V
min. rated control voltage Us with DC: 17 - 32 V
Number of auxiliary contacts as opener: 0
Number of auxiliary contacts as shutter: 1
Number of main contacts as opener: 0
Number of making contacts and main contacts: 3
Type of actuation: DC
Connection type: Other
suitable for series installation: false