Catalog navigation
CAD-Modellauswahl
Auswählbare Produkte: 3
HELP_VARIABLE
Company
ABB Low Voltage & Systems
Description
SK1-K - Signal Contact
Bill of material
ABB - 1SAM201903R1203 + SK1-02K Signaling Contact 2 NC with Push-In terminals
Product Id
Extended Product Type
Invoice Description
Type
SK1-K
Description
Signal Contact, for lateral mounting at the right; push-in
Short Description
Long Description
Signaling contacts SK1-K with Push-in spring terminals signal the tripping of the manual motor starter. For SK1 the indication on the device itself is done with a protruding orange button. The contact positions of SK1 need to be manually reset after a tripping event by pushing the orange button. SK1-K signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1-K are available as normally open or normally closed contacts.
International product number
Product number of the Manufacturer
Manufacturer Name
ABB
Number of contacts as change-over contact
0
Number of contacts as normally open contact
Number of contacts as normally closed contact
Number of fault-signal switches
1
Rated operation current Ie at AC-15, 230 V
4 A
Type of electric connection
Spring clamp connection
Model
Top mounting
Mounting method
Side mounting
Lamp holder
None
Customs tariff number
85365080
Deeplink product page
Link to product detail page
Procurement
Last updateOct 18, 2023, 7:40 PM
Artikelnummer1SAM201903R1203
AUSSCHREIBEN.DEhttps://ausschreiben.de/catalog/abb/catalogItem/96eaf24d-61c1-46ae-a5f0-75ec44413099
Währung:
$
£
¥
CN¥
Alle Angaben ohne Gewähr
Letzte Aktualisierung: Oct 18, 2023, 7:40 PM
Preview - Generation
Vorschau
3D
2D

Klassifikationen
CNS
Sachmerkmal Eigenschaften:
Bestellnummer: 1SAM201903R1203
Description long: Signaling contacts SK1-K with Push-in spring terminals signal the tripping of the manual motor starter. For SK1 the indication on the device itself is done with a protruding orange button. The contact positions of SK1 need to be manually reset after a tripping event by pushing the orange button. SK1-K signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1-K are available as normally open or normally closed contacts.
Description short: SK1-02K Signaling Contact 2 NC
Manufacturer / brand name: ABB
Product website: Link to product detail page
Zolltarifnummer: 85365080
ETIM 8.0
Hilfsschalterblock:
Montageart: Side mounting
Ausführung: Top mounting
Fassung: None
Bemessungsbetriebsstrom Ie bei AC-15, 230 V: 4 A
Ausführung des elektrischen Anschlusses: Spring clamp connection
Anzahl der Fehlersignalschalter: 1
Anzahl der Kontakte als Öffner: 2
Anzahl der Kontakte als Schließer: 0
Anzahl der Kontakte als Wechsler: 0