您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
jean-michel.eymery@fr.abb.com
確定
??
-
我的賬號
註冊
登錄
忘記密碼?
回饋
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
歡迎
CAD模型
Find a channel partner
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
歡迎
CAD模型
Find a channel partner
登錄
註冊
忘記密碼?
回饋
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
Catalog navigation
所有產品目錄
幾何搜索
可提供的產品目錄語言:
English
English
ABB - 1SAM340010R1003 + MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
ABB Low Voltage & Systems
Low Voltage Products & Systems
Control Products
Manual Motor Starters
Manual Motor Starters
Powered by
CAD模型選擇
生成CAD模型
生成PDF資料表
{abb_ww/low_voltage/control/manual_motor_starters/manual_motor_starters/ms132_k.prj},{NB=abb_1SAM340010R1003_MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10},{PN=1SAM340010R1003},{X=2},{CTN=85362010},{EXTTYPE=MS132-0.4KT},{INVDES=MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10},{TYPE=MS132-K, LE 10 A},{DES=Manual Motor Starter, Ie = 0.16 10 A; push-in},{LCP=Active},{DESCSHORT=MS132-0.4KT Circuit-breaker for primary}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
添加用於比較
可提供的產品: 41
HELP_VARIABLE
Company
ABB Low Voltage & Systems
Description
MS132-K - Manual Motor Starters
Bill of material
ABB - 1SAM340010R1003 + MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
Product Id
1SAM340010R1003
1SAM340010R1003
Extended Product Type
MS132-0.4KT
MS132-0.4KT
Invoice Description
MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
MS132-0.4KT Circuit-breaker for primary transformer protection,Trip Class 10
Type
MS132-K, Ie = ≤ 10 A
MS132-K, Ie = ≤ 10 A
Description
Manual Motor Starter, Ie = 0.16 … 10 A; push-in
Manual Motor Starter, Ie = 0.16 … 10 A; push-in
Short Description
MS132-0.4KT Circuit-breaker for primary
MS132-0.4KT Circuit-breaker for primary
Long Description
The circuit breaker for transformer protection MS132-0.4KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
The circuit breaker for transformer protection MS132-0.4KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
International product number
4013614535130
4013614535130
Product number of the Manufacturer
1SAM340010R1003
1SAM340010R1003
Manufacturer Name
ABB
Rated voltage
690, 690
690, 690
V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100
100
kA
With thermal protection
Phase failure sensitive
Overload release current setting
0.25, 0.40
0.25, 0.40
A
Adjustment range short-term delayed short-circuit release
-, -
-, -
A
Switch off technique
Rated operating voltage
V
Adjustment range undelayed short-circuit release
8, 8
8, 8
A
Rated permanent current Iu
0.4
0.4
A
Rated operation power at AC-3, 400 V
kW
Type of electrical connection of main circuit
Type of control element
Device construction
With integrated auxiliary switch
With integrated under voltage release
Number of poles
Rated short-circuit breaking capacity lcu at 400 V, AC
kA
Degree of protection (IP)
Height
mm
Width
mm
Depth
mm
Customs tariff number
85362010
Deeplink product page
Link to product detail page
Procurement
Last update
Oct 18, 2023, 7:40 PM
Part number
1SAM340010R1003
AUSSCHREIBEN.DE
https://ausschreiben.de/catalog/abb/catalogItem/d8831063-dc1b-40a3-9b23-1a6e0f5f5ff3
Currency:
$
€
₩
CN¥
¥
£
Calculate
Cancel
All information without guarantee.
Last update: Oct 18, 2023, 7:40 PM
Preview - Generation
預覽
3D
2D
分類
CNS
Object Properties:
Order Number:
1SAM340010R1003
Description long:
The circuit breaker for transformer protection MS132-0.4KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
Description short:
MS132-0.4KT Circuit-breaker for primary
Manufacturer / brand name:
ABB
Product website:
Link to product detail page
Customs Tariff Number:
85362010
ETIM 8.0
Motor protection circuit-breaker:
Width:
mm
Height:
mm
Depth:
mm
Rated operation power at AC-3, 400 V:
kW
With integrated auxiliary switch:
Rated permanent current Iu:
0.4
A
With integrated under voltage release:
Number of poles:
Rated operating voltage:
V
Overload release current setting:
0.25, 0.40
A
Degree of protection (IP):
With thermal protection:
Type of electrical connection of main circuit:
Type of control element:
Switch off technique:
Rated short-circuit breaking capacity lcu at 400 V, AC:
kA
Adjustment range undelayed short-circuit release:
8, 8
A
Phase failure sensitive:
Device construction:
Power circuit-breaker for trafo/generator/installation protection:
Rated permanent current Iu:
0.4
A
Overload release current setting:
0.25, 0.40
A
Rated voltage:
690, 690
V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz:
100
kA
Adjustment range short-term delayed short-circuit release:
-, -
A
Adjustment range undelayed short-circuit release:
8, 8
A