Catalog navigation
All catalogs
Geometric Search
CAD model selection
Add for comparison
Selectable products: 60
Company
ABB Low Voltage & Systems
Description
MS116 - Manual Motor Starters
Bill of material
ABB - 1SAM250000U1012 + MS116-12 Manual Motor Starter Trip class 10A, 8.0 ... 12A
Product Id
1SAM250000U1012
Extended Product Type
MS116-12
Invoice Description
MS116-12 Manual Motor Starter Trip class 10A, 8.0 ... 12A
Type
MS116
Description
Manual Motor Starter, Ie = 0.16 ... 16 A
Short Description
MS116-12 Manual Motor Starter
Long Description
International product number
4013614495489
Product number of the Manufacturer
1SAM250000U1012
Manufacturer Name
ABB
Overload release current setting
-, -
A
Adjustment range undelayed short-circuit release
-, -
A
With thermal protection
Phase failure sensitive
Switch off technique
Rated operating voltage
-, -
V
Rated permanent current Iu
A
Rated operation power at AC-3, 400 V
kW
Type of electrical connection of main circuit
Type of control element
Device construction
With integrated auxiliary switch
With integrated under voltage release
Number of poles
Rated short-circuit breaking capacity lcu at 400 V, AC
kA
Degree of protection (IP)
Height
mm
Width
mm
Depth
mm
Customs tariff number
85362010
Deeplink product page
Preview - Generation
Preview
3D
2D

Classifications
ETIM 10.0
Motor protection circuit-breaker:
Width: mm
Height: mm
Depth: mm
Rated operation power at AC-3, 400 V: kW
With integrated auxiliary switch:
Rated permanent current Iu: A
With integrated under voltage release:
Number of poles:
Rated operating voltage: -, - V
Overload release current setting: -, - A
Degree of protection (IP):
With thermal overload protection:
Type of electrical connection of main circuit:
Type of control element:
Switch off technique:
Rated short-circuit breaking capacity Icu at 400 V, AC: kA
Adjustment range undelayed short-circuit release: -, - A
Phase failure sensitive:
Device construction:
CNS
Object Properties:
Order Number: 1SAM250000U1012
Description long: The MS116-12 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 12.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
Description short: MS116-12 Manual Motor Starter
Manufacturer / brand name: ABB
Product website:
Customs Tariff Number: 85362010
GTIN-Code: 4013614495489
ETIM 8.0
Motor protection circuit-breaker:
Width: mm
Height: mm
Depth: mm
Rated operation power at AC-3, 400 V: kW
With integrated auxiliary switch:
Rated permanent current Iu: A
With integrated under voltage release:
Number of poles:
Rated operating voltage: -, - V
Overload release current setting: -, - A
Degree of protection (IP):
With thermal protection:
Type of electrical connection of main circuit:
Type of control element:
Switch off technique:
Rated short-circuit breaking capacity lcu at 400 V, AC: kA
Adjustment range undelayed short-circuit release: -, - A
Phase failure sensitive:
Device construction:
ETIM 9.0
Motor protection circuit-breaker:
Width: mm
Height: mm
Depth: mm
Rated operation power at AC-3, 400 V: kW
With integrated auxiliary switch:
Rated permanent current Iu: A
With integrated under voltage release:
Number of poles:
Rated operating voltage: -, - V
Overload release current setting: -, - A
Degree of protection (IP):
With thermal overload protection:
Type of electrical connection of main circuit:
Type of control element:
Switch off technique:
Rated short-circuit breaking capacity lcu at 400 V, AC: kA
Adjustment range undelayed short-circuit release: -, - A
Phase failure sensitive:
Device construction:
eclass
27-37-04-01 - Motor protection circuit-breaker:
Release system:
Rated operating power with AC-3, 400 V: kW
rated permanent current: A
rated limit short-circuit switch-off current Icu with 400 V, 50 AC: kA
Greatest value of overload release adjustment range: -, - A
Device type:
Sensitive to phase failure:
Lowest value of setting range for overload tripper: -, - A
Lowest value of setting range for short circuit tripper, undelayed: -, - A
Greatest value of tuning range short circuit tripper, undelayed: -, - A
rated current: -, - V
min. rated operating voltage: -, - V
thermal protection present:
Pole number:
height: mm
depth: mm
Connection type:
Integrated auxiliary switch present:
Integrated undervoltage tripper present:
Design of actuating element:
width: mm
degree of protection: