Catalog navigation
CAD-Modellauswahl
Auswählbare Produkte: 30
HELP_VARIABLE
Company
ABB Low Voltage & Systems
Description
MO132 - Manual Motor Starters
Bill of material
ABB - 1SAM360000R1008 + MO132-4.0 Manual Motor Starter Magnetic only, 4.0A
Sellers P/N
Extended Product Type
Invoice Description
Sellers P/N
Manual Motor Starter Magnetic Only
Type
Description
Manual Motor Starter Magnetic Only
Ampere Rating UL/CSA
A
ATEX Certificate
-
Connecting Capacity Main Circuit Header
Connecting Capacity Main Circuit Value
mm²
Customs tariff number
85362010
Electrical Durability
50000 Cycle
ETIM 6
EC000074 - Motor protection circuit-breaker
Mechanical Durability
100000 Cycle
Mounted Auxiliary Contacts
-
Phase Loss Sensitive
No
Power Loss Header
at Rated Operating Conditions per Pole
Power Loss Value
W
Product Net Weight
kg
Rated Current
A
Rated Instantaneous Short-Circuit Current Setting
A
Rated Insulation Voltage
690 V
Rated Operational Power AC-3 Header
(400 V) Three Phase
Rated Operational Power AC-3 Value
kW
Rated Operational Voltage Header
Main Circuit
Rated Operational Voltage Value
690 V
Rated Service Short-Circuit Breaking Capacity Header
Rated Service Short-Circuit Breaking Capacity Value
230.000 kA
Rated Ultimate Short-Circuit Breaking Capacity Header
Rated Ultimate Short-Circuit Breaking Capacity Value
100.000 kA
Rated Uninterrupted Current
A
Setting Range
-
Trip Class
-
UNSPSC
39121521
Short Description
Long Description
International product number
Product number of the Manufacturer
Manufacturer Name
ABB
Overload release current setting
A
Adjustment range undelayed short-circuit release
A
With thermal protection
false
Phase failure sensitive
false
Switch off technique
Magnetic
Rated operating voltage
690, 690 V
Rated permanent current Iu
A
Rated operation power at AC-3, 400 V
kW
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Device construction
Complete device in housing
With integrated auxiliary switch
false
With integrated under voltage release
false
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, AC
kA
Degree of protection (IP)
IP20
Height
mm
Width
45 mm
Depth
mm
Deeplink product page
Link to product detail page
Preview - Generation
Vorschau
3D
2D

Klassifikationen
CNS
Sachmerkmal Eigenschaften:
Bestellnummer: 1SAM360000R1008MO132-4.0 Manual Motor Starter Magnetic only, 4.0A
Description long: The MO132-4.0 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 4.00 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
Description short: MO132-4.0 Manual Motor Starter
Manufacturer / brand name: ABB
Product website: Link to product detail page
Zolltarifnummer: 85362010
ETIM 8.0
Leistungsschalter für Motorschutz:
Breite: 45 mm
Höhe: 90 mm
Tiefe: 86.75 mm
Bemessungsbetriebsleistung bei AC-3, 400 V: 1.5 kW
Mit integriertem Hilfsschalter: false
Bemessungsdauerstrom Iu: 4 A
Mit integriertem Unterspannungsauslöser: false
Polzahl: 3
Bemessungsbetriebsspannung: 690, 690 V
Überlastauslöser Stromeinstellung: 4, 4 A
Schutzart (IP): IP20
Mit thermischem Schutz: false
Anschlussart Hauptstromkreis: Screw connection
Ausführung des Betätigungselements: Turn button
Auslösetechnik: Magnetic
Bemessungsgrenzkurzschlussausschaltstrom Icu bei 400 V, AC: 100 kA
Einstellbereich des unverzögerten Kurzschlussauslösers: 50, 50 A
Phasenausfallempfindlich: false
Gerätebauart: Complete device in housing