Catalog navigation
CAD model selection
Selectable products: 1
HELP_VARIABLE
Company
ABB Low Voltage & Systems
Description
ASL12..S - 3-pole Contactors - Spring Terminals - DC Operated
Bill of material
ABB - 1SBL113004R8101 + ASL12-30-01S-81 24VDC Contactor
Product ID
1SBL113004R8101
Extended Product Type
ASL12-30-01S-81
Invoice Description
ASL12-30-01S-81 24VDC Contactor
Description
Spring terminals
Long Description
ASL12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
International product number
3471523060111
Product number of the Manufacturer
1SBL113004R8101
Rated control supply voltage Us at AC 50HZ
- - - V
Rated control supply voltage Us at AC 60HZ
- - - V
Rated control supply voltage Us at DC
24, 24 V
Voltage type for actuating
DC
Rated operation current Ie at AC-1, 400 V
22 A
Rated operation current Ie at AC-3, 400 V
12 A
Rated operation power at AC-3, 400 V
5.5 kW
Modular version
false
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
1
Type of electrical connection of main circuit
Spring clamp connection
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
3
Customs tariff number
85364900
Deeplink product page
Link to product detail page
Type
ASL12-30-01S
Procurement
Last updateMay 9, 2025, 10:07 PM
Part number1SBL113004R8101
Currency:
$
£
¥
CN¥
All information without guarantee
Last update: May 9, 2025, 10:07 PM
Preview - Generation
Preview
3D
2D

Classifications
CNS
Object Properties:
Order Number: 1SBL113004R8101
Description long: ASL12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The ASL..S contactors are the spring terminal version of the ASL... range. The ASL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. ASL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Description short: ASL12-30-01S-81 24VDC Contactor
Manufacturer / brand name: ABB
Product website: https://new.abb.com/products/ABB1SBL113004R8101
Customs Tariff Number: 85364900
GTIN-Code: 3471523060111
ETIM 8.0
Power contactor, AC switching:
Modular version: false
Rated operation power at AC-3, 400 V: 5.5 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 0
Number of auxiliary contacts as normally closed contact: 1
Rated operation current Ie at AC-3, 400 V: 12 A
Rated operation current Ie at AC-1, 400 V: 22 A
Rated control supply voltage Us at AC 50HZ: - - - V
Rated control supply voltage Us at AC 60HZ: - - - V
Rated control supply voltage Us at DC: 24, 24 V
Type of electrical connection of main circuit: Spring clamp connection
Voltage type for actuating: DC
ETIM 9.0
Power contactor, AC switching:
Modular version: false
Rated operation power at AC-3, 400 V: 5.5 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 0
Number of auxiliary contacts as normally closed contact: 1
Rated operation current Ie at AC-3, 400 V: 12 A
Rated operation current Ie at AC-1, 400 V: 22 A
Rated control supply voltage AC 50 Hz: - - - V
Rated control supply voltage AC 60 Hz: - - - V
Rated control supply voltage DC: 24, 24 V
Type of electrical connection of main circuit: Spring clamp connection
Voltage type for actuating: DC
cadenas_class
:
eclass
27-37-10-03 - Power contactor, AC switching:
Rated operating power with AC-3, 400 V: 5.5 kW
Rated operating current Ie with AC-1, 400 V: 22 A
Rated operating current Ie with AC-3, 400 V: 12 A
max. rated control supply voltage Us: - - - V
min. rated control voltage Us with AC 50 Hz: - - - V
min. rated control voltage Us with AC 60 Hz: - - - V
min. rated control voltage Us with DC: 24, 24 V
Number of auxiliary contacts as opener: 1
Number of auxiliary contacts as shutter: 0
Number of main contacts as opener: 0
Number of making contacts and main contacts: 3
Type of actuation: DC
Connection type: Spring clamp connection
suitable for series installation: false