NF - Contactor relays - AC or DC Operated
Bill of material
ABB - 1SBH137001R1140 + NF40E-11 24-60V50/60HZ 20-60VDC Contactor Relay
Product Id
1SBH137001R1140
Extended Product Type
NF40E-11
Invoice Description
NF40E-11 24-60V50/60HZ 20-60VDC Contactor Relay
Type
NF(Z)40E
Description
Screw Terminals 4 Poles NF Contactor Relay - Top Mounted Coil Terminal
Short Description
NF40E-11 24-60V50/60HZ 20-60VDC Contactor Relay
Long Description
NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available. Note: NF..E-11 not suitable for a direct control by PLC-output. NF..E-11 type available in some countries: please consult your ABB representative.
International product number
3471523100015
Product number of the Manufacturer
1SBH137001R1140
Manufacturer Name
ABB
Rated control supply voltage Us at AC 50HZ
24, 60 V
Rated control supply voltage Us at AC 60HZ
24, 60 V
Rated control supply voltage Us at DC
20, 60 V
Voltage type for actuating
AC/DC
Rated operation current Ie, 400 V
3 A
Connection type auxiliary circuit
Screw connection
Mounting method
DIN-rail/screw
Interface
false
Number of auxiliary contacts as normally closed contact, delayed switching
0
Modular version
Number of auxiliary contacts as normally open contact, leading
0
Number of auxiliary contacts as normally open contact
4
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
With LED indication
false
Type of electrical connection of main circuit
Suitable for manual operation
false
Number of normally closed contacts as main contact
Number of normally open contacts as main contact
Customs tariff number
85364900
Deeplink product page
Link to product detail page
Procurement
By default all properties are visible
Use the checkboxes below to restrict the property list as you wish
Description
RFI
Last updateOct 18, 2023, 7:50 PM
Part number1SBH137001R1140
AUSSCHREIBEN.DEhttps://ausschreiben.de/catalog/abb/catalogItem/990c6ec5-ec24-4d33-87f5-b6f9ec1d136f
Currency:
$
£
¥
CN¥
All information without guarantee
Last update
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
CNS
Object Properties:
Order Number: 1SBH137001R1140
Description long: NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available. Note: NF..E-11 not suitable for a direct control by PLC-output. NF..E-11 type available in some countries: please consult your ABB representative.
Description short: NF40E-11 24-60V50/60HZ 20-60VDC Contactor Relay
Manufacturer / brand name: ABB
Product website: Link to product detail page
Customs Tariff Number: 85364900
ETIM 8.0
Power contactor, AC switching:
Modular version:
Number of normally open contacts as main contact:
Number of normally closed contacts as main contact:
Number of auxiliary contacts as normally open contact: 4
Number of auxiliary contacts as normally closed contact: 0
Rated control supply voltage Us at AC 50HZ: 24, 60 V
Rated control supply voltage Us at AC 60HZ: 24, 60 V
Rated control supply voltage Us at DC: 20, 60 V
Type of electrical connection of main circuit:
Voltage type for actuating: AC/DC
Contactor relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 4
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage Us at AC 50HZ: 24, 60 V
Rated control supply voltage Us at AC 60HZ: 24, 60 V
Rated control supply voltage Us at DC: 20, 60 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: AC/DC